NGV-CYL-JA22
ISO 11439
statement
The
rate of pressurization shall not exceed 14 bar/s at pressures in excess of 80 %
of the design burst pressure. If the rate of pressurization at pressures in
excess of 80 % of the design burst pressure exceeds 3,5 bar/s, then either the
cylinder shall be placed schematically between the pressure source and the
pressure measurement device, or there shall be a 5 s hold at the minimum design
burst pressure.
The
minimum required (calculated) burst pressure shall be at least 450 bar, and in
no case less than the value necessary to meet the stress ratio requirements.
Actual burst pressure shall be recorded. Rupture may occur in either the
cylindrical region or the dome region of the cylinder.
DESCRIPTION OF MACHINE
The
machine includes
two
parts: insulated
chamber and control unit. The
internal
surfaces of the chamber are made of FRP.
The tested cylinder inside can be pressurized
and pressure cycled hydrostatically
pressurized to 300 bar or more.
SPECIFICATION
1.
The machine can be used to test the CNG cylinders according to ISO11439 Annex
A (normative) Test methods and criteria A.12 Hydrostatic pressure burst test.
2.
Control station : 1 m x 0,98 m x
1,5 m
3.
Hydraulic Pump with:
·
1034 bar max pressure
·
0 – 4,5 GPM Capacity
·
440 CSS plunger
·
SS 303 body material
·
UMHWPE Seal
·
Water as working liquid
4.
The machine can be used to test the CNG
cylinder of size: diameter 406
mm and length 1.8 m maximum.
5.
The tested cylinder inside the chamber
can be hydrostatically pressurized to
300 bar or more.
6.
Close chamber with sight window
7.
The machine includes two parts:
insulated enclosed chamber (tank) and
control unit.
8.
The internal dimension of the enclosed chamber
(tank) is 2 x 0.6 x 0.9 m.
9. The machine is automatically controlled by software.
10.
The machine can measure the pressure during test.
11.
The machine is controlled by the control software running on Windows
OS. The test result is reported as
number or
graph
and printed out on the printer.
12.
The machine is operated by 220-230
VAC 1 phase 50 Hz and 380 VAC 3
phase 50Hz.
Please consult with our
local agent to determine your requirement.